Default Value: conf/dcm4chee-ae
#MergePatientStudySeriesAttributesFromDB
Anchor | ||||
---|---|---|---|---|
|
Defines, if Patient, Study and Series attributes are merged from corresponding DB records into the generated Multi-frame image, so they need not be specified in upgrade-XX.xml to be copied from the Single-frame images to the generated Multi-frame image. Attributes not specified in upgrade-XX.xml are not verified for equality of values over all source images. Therefore, skipping such attributes from upgrade-XX.xml allows the generation of the Multi-frame image even if the attribute value differs between source images.
Series Instance UID is never merged from the DB, so it can be defined by upgrade-XX.xml - including an entry for the Series Instance UID attribute or not - if the generated Multi-frame image shall be put into the same Series as the source images, or not.
Default Value: true
#NoPixelData
Anchor | ||||
---|---|---|---|---|
|
Defines, if the generated Multi-frame image is stored without pixel data with DICOM Transfer Syntax: No Pixel Data [Deflate] without pixel data.
If false
, pixel data is copied from the original Single-frame images into the generated Multi-frame image.
...
#FileSystemMgtName
Anchor | ||||
---|---|---|---|---|
|
Used internally. Do NOT modify.
...
Used internally. Do NOT modify.
...